U-031 Quad Gate-to-Trig converter (4HP)


DSC_0621_u-031 DSC_0623_u-031_jumpers

 

U-031 Gate-to-trig converter – quad (4 independent sections).

Makes fixed 5V triggers from rising edge of incoming gate signal.
Trigger lengths can be set using jumpers (binary meaning) from 1ms to 31ms common to all sections (for example 1ms and 4ms jumpers set: 1+4=5ms triggers). Length is determined by “sum” of jumpers set. For 12ms length should be jumpers “4ms” and “8ms” set, all other jumpers removed. Setting limit length (max.) in random mode works same way (for generation random trigger length up to 20ms should be jumpers “16ms” + “4ms” set, all others removed).
Shortest trigger (no jumper set) is about 250us (0,25ms).
Independent “random” jumper to make random trigger length from 250us to maximum time set by five “time” jumpers. Each incomming trig generates its own length regardless of channel in random mode.

Width: 4TE/ 4HP/ 20mm.
Depth: 40mm /1,6″ max.
Current: 20mA max. (from positive +12V supply only)
Handy 20cm (8″) power cable included.

Double check power connection before powering your system please.
„Red strip“ means -12V connector side in Eurorack standards.
In some power distribution systems connector key can be reverted. In this case cut connector key and plug power connector right way (with respect to red strip) or use different power cable appropriate to your power system.

Order Quad Gate-to-Trig converter