P-310 BNC outputs/bus access (4HP) – discontinued


DSCN6663_P-310_bnc DSCN6658_p-310_jumpers

 

Eurorack BNC outputs. Can be used for oscilloscope connection or for direct access to CV &.Gate bus board signals (in/out).

Gate jack & BNC (can be connected to power bus board.Gate signal by internal jumper)
CV jack & BNC (can be connected to power bus board CV signal by internal jumper)
+5V, +12V and -12V power supply BNC outputs for noise/ripple/overload monitoring by scope

CV and Gate signals connection to bus board mode can be selected by internal jumpers:
– jumper set in top position = normalled connection to bus. If front panel jack is plugged-in it will disconnect BNC and jack from bus (jack and BNC are wired together)
– jumper set in bottom position = hardwired jack and BNC to bus board (jack can be used to direct CV/gate in/out to/from bus board in this mode)
– no jumper installed =  jack and BNC connected together but isolated from bus board

 

Width: 4TE/ 4HP/ 20mm
Depth: 25mm /1″ max.
Current: 0mA (passive)
Power cable included.

Double check power connection before powering your system please.
„Red strip“ means -12V connector side in Eurorack standards.
In some power distribution systems connector key can be reverted.
In this case cut connector key and plug power connector right way (with respect to red strip) or use different power cable appropriate to your power system.

 

Out of Stock